2019 Ranger Tug 27- Battery Charger

Esperance

New member
Joined
May 18, 2023
Messages
1
Fluid Motion Model
C-28
Hull Identification Number
FMLT2766C919
Vessel Name
Esperance
Hello everyone- quick question for the group. I have a Kisae 20A battery charger which stopped working. It is showing Code- E03. According to the Kisae manual, that code is "Battery is connected backwards". I double checked all of the connections and I am sure that nothing is connected backwards. Anyone run into this previously? Thanks.
 
Hello everyone- quick question for the group. I have a Kisae 20A battery charger which stopped working. It is showing Code- E03. According to the Kisae manual, that code is "Battery is connected backwards". I double checked all of the connections and I am sure that nothing is connected backwards. Anyone run into this previously? Thanks.
Did you ever get a answer?
This is happening to me now. Double checked all battery connections. I did just replace the house bank batteries. I have no idea why it thinks it is reversed?
 
I fixed my E03 problem.
Procedure:
  • Turn OFF/Disconnect AC
  • Disconnect Channel 1 (House Bank Positive)
  • Wait 10 seconds
  • Reconnect Channel 1
  • Disconnect Common (Ground)
  • Wait 10 Seconds
  • Reconnect Common
  • Turn ON/Reconnect AC

Fixed.

Seems to me it was mad that I essentially replaced all battery banks, and E03 is a default (I don’t know what to do) Error code.
 